Table ldc, Table hdc – AMETEK Compact i/iX Series Software Manual User Manual
Page 122
User Manual
– Rev H
California Instruments
122
Avionics Software
Test No. Section
Subject
Test Limits
Comment
File Ref.
1
One Phase Power Failures
0V for 7 seconds
Table TAC602-2 A-F
BTAC602-1
2
Two Phase Power Failures
0V for 30 mins
Table TAC602-2 G-J
BTAC602-2
TAC603
Phase Reversal
N/A to Rev B
5.3.5.3
Table LDC:
Test No. Section
Subject
Test Limits
Comment
File Ref.
LDC101
Load Measurements
28V DC
BLDC101
LDC102
Steady State Limits for Voltage
22V to 29V DC
Apply for 30 mins
BLDC102
LDC103
Voltage Distortion Spectrum
Requires Additional Equipment
LDC104
Total Ripple
Requires Additional Equipment
LDC105
Normal Voltage Transients
18V to 50V DC
1
Overvoltage Transients
Peak Voltage 50V DC
Table LDC105-3 AA-JJ
BLDC105-1
2
Undervoltage Transients
Low Voltage 18V DC
Table LDC105-3 KK-PP
BLDC105-2
3
Combined Transients
18V to 50V DC
Table LDC105-3 QQ-RR
BLDC105-3
4
Repetitive Normal Voltage Transient Test
18V to 45V DC
Repeat transient for 30 mins
BLDC105-4
LDC201
Power Interrupt
0V for 50 msec
Table LDC201-2 A-L
BLDC201
LDC301
Abnormal Steady State Limits for Voltage
20V to 31.5V DC
Apply each test for 30 mins
BLDC301
LDC302
Abnormal Voltage Transients
7V to 50V DC
1
Overvoltage Transients
Peak Voltage 50V DC
Table LDC302-3 AA-FF
BLDC302-1
2
Undervoltage Transients
Low Voltage 7V DC
Table LDC302-3 GG-LL
BLDC302-2
3
Combined Transients
7V to 50V DC
Table LDC302-3 MM-NN
BLDC302-3
LDC401
Emergency Limits for Voltage
18V to 29V DC
Apply each test for 30 mins
BLDC401
LDC501
Starting Voltage Transients
16V to 30V DC
Table LDC501-2 A
BLDC501
LDC601
Power Failure
0V for 7 seconds
Table LDC601-2 A-D
BLDC601
LDC602
Polarity Reversal
N/A to Rev B
5.3.5.4
Table HDC:
Test No. Section
Subject
Test Limits
Comment
File Ref.
HDC101
Load Measurements
270V DC
BHDC101
HDC102
Steady State Limits for Voltage
250V to 280V DC
Apply for 30 mins
BHDC102
HDC103
Voltage Distortion Spectrum
Requires Additional Equipment
HDC104
Total Ripple
Requires Additional Equipment
HDC105
Normal Voltage Transients
125V to 475V DC
1
Overvoltage Transients
Peak Voltage 475V DC
Table HDC105-1 A-J
BHDC105-1
2
Undervoltage Transients
Low Voltage 125V DC
Table HDC105-1 K-P
BHDC105-2
3
Combined Transients
125V to 475V DC
Table HDC105-1 Q-R
BHDC105-3
4
Repetitive Normal Voltage Transient Test
215V to 315V DC
Repeat transient for 30 mins
BHDC105-4
HDC201
Power Interrupt
0V for 50 msec
Table HDC201-2 A-L
BHDC201
HDC301
Abnormal Steady State Limits for Voltage
245V to 285V DC
Apply each test for 30 mins
BHDC301
HDC302
Abnormal Voltage Transients
65V to 475V DC
1
Overvoltage Transients
Peak Voltage 475V DC
Table HDC302-2 A-F
BHDC302-1
2
Undervoltage Transients
Low Voltage 65V DC
Table HDC302-2 G-L
BHDC302-2