Parameter Editor GUI Setting

CLI Parameter

Description

Name

Legal Values

Name

Legal

Values

(1)

Use reset signal to

stop output strobe

USE_OUTPUT_STROBE_

RESET

true

false

This setting stops the

unidirectional output

strobe using a user-

provided reset signal. The

core_clock_in

and the

reset_n_core_clock_in

signals are required.

OCT Source

Output Strobe

Enable
Data Write

Enable
Dedicated

OCT Enable

OCT_SOURCE

0

1

2

This setting specifies the

type of input signal to

toggle the OCT control:
Output Strobe Enable

—Uses the

output_

strobe_ena

input as

the OCT control signal.

Data Write Enable

Uses the

write_oe_in

input as the OCT

control signal.

Dedicated OCT

Enable—Adds a

oct_

ena_in

input to the

interface, which is used

as the OCT control

signal.

The availability of the

Output Strobe Enable,

Data Write Enable,and

Dedicated OCT Enable

are dependent on

PIN_

TYPE

and

USE_BIDIR_

STROBE

parameters.

Default value is Data

Write Enable.

(1)

All CLI parameter values are type string, therefore you must enclose the values in double quotes.