Altera ALTDQ_DQS2 User Manual
Page 16

Parameter Editor GUI Setting
CLI Parameter
Description
Name
Legal Values
Name
Legal
Values
(1)
Use reset signal to
stop output strobe
—
USE_OUTPUT_STROBE_
RESET
true
false
This setting stops the
unidirectional output
strobe using a user-
provided reset signal. The
core_clock_in
and the
reset_n_core_clock_in
signals are required.
OCT Source
Output Strobe
Enable
Data Write
Enable
Dedicated
OCT Enable
OCT_SOURCE
0
1
2
This setting specifies the
type of input signal to
toggle the OCT control:
• Output Strobe Enable
—Uses the
output_
strobe_ena
input as
the OCT control signal.
• Data Write Enable—
Uses the
write_oe_in
input as the OCT
control signal.
• Dedicated OCT
Enable—Adds a
oct_
ena_in
input to the
interface, which is used
as the OCT control
signal.
The availability of the
Output Strobe Enable,
Data Write Enable,and
Dedicated OCT Enable
are dependent on
PIN_
TYPE
and
USE_BIDIR_
STROBE
parameters.
Default value is Data
Write Enable.
(1)
All CLI parameter values are type string, therefore you must enclose the values in double quotes.
16
ALTDQ_DQS2 Parameter Settings
UG-01089
2014.12.17
Altera Corporation
ALTDQ_DQS2 IP Core User Guide