beautypg.com

Altdq_dqs2 parameter settings – Altera ALTDQ_DQS2 User Manual

Page 11

background image

Related Information

Altera IP Release Notes

ALTDQ_DQS2 Parameter Settings

You can instantiate and parameterize using the IP Catalog and parameter editor GUI, or the

ip-generate

command through the command-line interface (CLI).
The following table lists the ALTDQ_DQS2 parameter settings.

Table 3: ALTDQ_DQS2 Parameter Settings

Parameter Editor GUI Setting

CLI Parameter

Description

Name

Legal Values

Name

Legal

Values

(1)

General Settings
Pin width

1 to 36

PIN_WIDTH

1 to 36

This setting specifies the

number of data (DQ) pins

to make as part of this

DQS group.
The default value is 9 (

9

).

Pin type

input
output
bidir

PIN_TYPE

input

output

bidir

This setting specifies the

direction of the data pins

(input, output, or bidirec‐

tional).
The default value is bidir

(

bidir

).

Extra output-only

pins

036

EXTRA_OUTPUT_WIDTH

0 to 36

This setting specifies the

extra output pins that you

need as part of a DQS

group.
A common use for this

setting is to add datamask

pins.
The default value is 0 (

0

).

(1)

All CLI parameter values are type string, therefore you must enclose the values in double quotes.

UG-01089

2014.12.17

ALTDQ_DQS2 Parameter Settings

11

ALTDQ_DQS2 IP Core User Guide

Altera Corporation

Send Feedback