Table 3: ALTDQ_DQS2 Parameter Settings
Parameter Editor GUI Setting
CLI Parameter
Description
Name
Legal Values
Name
Legal
Values
(1)
General Settings
Pin width
1 to 36
PIN_WIDTH
1 to 36
This setting specifies the
number of data (DQ) pins
to make as part of this
DQS group.
The default value is 9 (
9
).
Pin type
input
output
bidir
PIN_TYPE
input
output
bidir
This setting specifies the
direction of the data pins
(input, output, or bidirec‐
tional).
The default value is bidir
(
bidir
).
Extra output-only
pins
0 – 36
EXTRA_OUTPUT_WIDTH
0 to 36
This setting specifies the
extra output pins that you
need as part of a DQS
group.
A common use for this
setting is to add datamask
pins.
The default value is 0 (
0
).
(1)
All CLI parameter values are type string, therefore you must enclose the values in double quotes.