25.
TRANSMISSION HOUSING:
25.1. Place suitable drain containers under the trans-
mission housing. See Figure 25.1.
25.2. Rotate the transmission housing until the front
portion is facing down.
25.3. Allow all of the hydraulic fluid to drain.
25.4. Remove all four hex cap screws securing the
drawbar bracket to the transmission housing
using a 3/4” socket. See Figure 25.4.
NOTE: Loctite™ the threads and torque them
between 360 and 420 In. Lbs. during assembly
25.5. Remove the drawbar bracket.
Figure 25.1
Drain Containers
Transmission Housing
Figure 25.4
Hex Cap Screws
Drawbar Bracket
25.6. Remove all three hex cap screws securing the
right and left lower hitch brackets to the trans-
mission housing using a 3/4” socket. See Figure
25.6.
NOTE: Loctite™ the threads and torque them
between 360 and 420 In. Lbs. during assembly
25.7. Remove the right and left lower hitch brackets.
25.8. Remove the duct tape covering the hydro suc-
tion tube’s straight fitting. See Figure 25.8.
25.9. Remove the hydro suction tube’s straight fitting
from the transmission housing using a 1”
wrench.
Figure 25.6
Hex Screws
Lower Hitch
Bracket
Transmission Housing
Figure 25.8
Hydro Suction Tube’s Straight Fitting
6