Cub Cadet SLTX1000 Series User Manual
Page 172

LTX Tractors
166
6.
Regulator/rectifier check: See Figure 7.35.
6a.
Check the ground.
•
With the engine running and the stator leads re-
connected to the regulator/rectifier, perform a
ground-side voltage-drop test from the regulator/
rectifier to the engine block.
•
If the voltage reading is greater than 0.1 Volts
D.C., replace or properly fasten the ground wire
that connects the regulator/rectifier to the engine
block. Retest to confirm good connection.
6b.
Bench Test: See Figure 7.36.
•
Set a digital multimeter to read on the X100
Ω
scale.
•
With the key switch OFF and the fuse removed,
unplug all the wires from the regulator/rectifier.
•
Remove the regulator/rectifier from the engine
(not strictly necessary, but provides easy
access).
•
Make the resistance tests described in the
accompanying table.
•
B+ is the D.C. terminal
•
A.C.1 is the A.C. terminal nearest B+
•
A.C.2 is the A.C. terminal furthest from B+
Figure 7.35
Figure 7.36
A.C.2 A.C.1 B+