PTO relay

The PTO relay is located on the main harness, underneath
the electric PTO switch. See Figure 7.10.

The PTO relay disengages the PTO clutch when it is

energized and latches on until the PTO switch is turned-
off. The list below details the function of the PTO relay.

3 Green wire

COM (Common) terminal

Ground for PTO clutch (not energized) or relay
latch (energized). Hard-wired to ground

5 White/black trace

Normally Open (N.O.) ter-
minal

Connects to COM terminal when the relay is ener-
gized. Power from PTO switch B-N.O. when PTO is
ON.

2 Red wire

Power for windings

Hot when the key switch is in any position other than
OFF.

4 White wire

Normally Closed (N.C.) ter-
minal

Connects PTO clutch to its ground path (through 30)
when the relay is not energized.

1 Yellow/black trace

Ground path for windings

Receives a ground when the seat is empty and the
PTO is turned ON. It also receives a ground signal
from the reverse switch when the tractor is put into
reverse with the PTO engaged, unless the RMC
module is turned ON.

Figure 7.10

PTO relay

Electric PTO switch

2 4 1

3

5

Relay

Relay terminal

pattern

Figure 7.10