Pto relay – Cub Cadet SLTX1000 Series User Manual
Page 156
LTX Tractors
150
PTO relay
The PTO relay is located on the main harness, underneath
the electric PTO switch. See Figure 7.10.
The PTO relay disengages the PTO clutch when it is
energized and latches on until the PTO switch is turned-
off. The list below details the function of the PTO relay.
3 Green wire
COM (Common) terminal
Ground for PTO clutch (not energized) or relay
latch (energized). Hard-wired to ground
5 White/black trace
Normally Open (N.O.) ter-
minal
Connects to COM terminal when the relay is ener-
gized. Power from PTO switch B-N.O. when PTO is
ON.
2 Red wire
Power for windings
Hot when the key switch is in any position other than
OFF.
4 White wire
Normally Closed (N.C.) ter-
minal
Connects PTO clutch to its ground path (through 30)
when the relay is not energized.
1 Yellow/black trace
Ground path for windings
Receives a ground when the seat is empty and the
PTO is turned ON. It also receives a ground signal
from the reverse switch when the tractor is put into
reverse with the PTO engaged, unless the RMC
module is turned ON.
Figure 7.10
PTO relay
Electric PTO switch
2 4 1
3
5
Relay
Relay terminal
pattern
Figure 7.10