Programmer Operation
Installation and Operation Handbook
5-14
2408 and 2404 Controller
Ramp rate
Ramp rate for ‘
rmP.r’ segments
Using
or
, set a value for the ramp rate, ranging from 0.0 to
999.9. The units are the ramp units (
rmP.U) set earlier in this
sequence.
Press
Duration time
Time for a ‘
dwEl’ segment, or time to target for a ‘rmP.t’
segment.
Set the time using
or
. You have set the units earlier in
this sequence. [‘
dwL.U’ defines the units for ‘dwEl’ segments:
‘
rmP.U’ defines the units for ‘rmP.t’ segments.]
Press
Called program number
Only appears for ‘
cALL’ segments.
(multi-program controllers only)
Set a called program number from 1 to 4, or from 1 to 20, using
or
.
Press
Number of cycles of the cALLed program
Only appears for ‘
cALL’ segments.
(multi-program controllers only)
Sets the number of cycles of the cALLed program from 1 to 999,
using
or
.
Press
Continued on the next page.