Ordering Code

Installation and Operation Handbook

A-4

2416 Controller

-

Hardware

coding

Part 2: Configuration

Sensor input

Range min

Range max

Units

Options

K

0

1000 C

CF

Notes:

1.

PDSIO is a proprietary technique developed by Eurotherm for bi-directional
transmission of analogue and digital data between instruments.

Mode 1: provides logic heating to a Eurotherm TE10S solid state relay with feedback of a

general load fault alarm.

Mode 2: provides logic heating to a Eurotherm TE10S solid state relay with feedback of load

current and two alarms: solid state relay failure and heater circuit failure.

2.

Range min and Range max: Thermocouple and RTD sensor inputs will always display
over the full operating range shown in Sensor input table. For these inputs, the values
entered here are the low and high setpoint limits. For process inputs, the values are the
display scaling corresponding to the minimum and maximum input values.

See note 2

Continued

Sensor input

Range min &max

Standard sensor inputs

°C

°F

J

J thermocouple

-210 to 1200

-340 to 2192

K

K thermocouple

-200 to 1372

-325 to 2500

T

T thermocouple

-200 to 400

-325 to 750

L

L thermocouple

-200 to 900

-325 to 650

N

N thermocouple

-250 to 1300

-418 to 2370

R

Type R - Pt13%Ph/Pt

-50 to 1768

-58 to 3200

S

Type S - Pt10%Rh/Pt

-50 to 1768

-58 to 3200

B

Type B - Pt30%Rh/Pt6%Rh

0 to 1820

32 to 3308

P

Platinel II

0 to 1369

32 to 2496

C

*Type C W5%Re/W26%Re
(Hoskins)*

0 to 2319

32 to 4200

Z

RTD/PT100

-200 to 850

-325 to 1562

Process inputs

F

-9.99 to + 80mV

0 to 9999

Y

0-20 mA Linear

0 to 9999

A

4-20 mA Linear

0 to 9999

W 0-5V DC Linear

0 to 9999

G

1-5V DC Linear

0 to 9999

V

0-10V DC Linear

0 to 9999

Custom Sensor inputs (* replaces type C thermocouple)
D

Type D - W3%Re/W25%Re

0 to 2399

32 to 4350

E

E thermocouple

-270 to 1000

-450 to 1830

1

Ni/Ni18%Mo

0 to 1399

32 to 2550

2

Pt20%Rh/Pt40%Rh

0 to 1870

32 to 3398

3

W/W26%Re (Englehard)

0 to 2000

32 to 3632

4 W/W26%Re

(Hoskins)

0 to 2010

32 to 3650

5 W5%Re/W26%Re

(Englehard)

10 to 2300

50 to 4172

6 W5%Re/W26%Re

(Bucose)

0 to 2000

32 to 3632

7

Pt10%Rh/Pt40%Rh

200 to 1800

392 to 3272

Options

Add as many options as required

Control options

NF On/Off

control

DP

Direct acting PID
control

PD Power

feedback

disabled

Cooling options

CF Fan

cooling

CW Water

cooling

CL Oil

cooling

Front panel buttons

MD Auto/man

button

disabled

RD Run/hold

button

disabled

Programmer options

HD

Dwell time in hours

HR

Ramp rate in units/hour

(minutes is standard)

Units

C

Centigrade

F Fahrenheit
K Kelvin
X Blank