Thermcraft XST-6-0-36-3V User Manual

Page 66

background image

Operation

Installation and Operation Handbook

2-16

2408 and 2404 Controller

Name Description

oP

Output list

Does not appear if Motorised Valve control
configured.
OP.Lo

Low power limit (%)

OP.Hi

High power limit (%)

OPrr

Output Rate Limit (% per sec)

FOP

Forced output level (%)

CYC.H

Heat cycle time (0.2S to 999.9S)

hYS.H

Heat hysteresis (display units)

ont.H

Heat output min. on-time (secs)
Auto (0.05S), or 0.1 - 999.9S

CYC.C

Cool cycle time (0.2S to 999.9S)

hYS.C

Cool hysteresis (display units)

ont.C

Cool output min. on-time (secs)
Auto (0.05S), or 0.1 - 999.9S

HC.db

Heat/cool deadband (display
units)

End.p To set power level in end

segment

Sb.OP

Sensor Break Output Power (%)

cmS

Comms list

Addr

Communications Address

cmS

DeviceNet (additional
parameters)

Nw.St Indicates network status

run

Network connected and
operational

rdy

Network connected but not
operational

oFF.L Network not connected





inFo Information list

diSP Configure lower readout of Home

display to show:
VPoS Valve position

Std Standard - display setpoint

AmPS Load current in amps

OP Output

Stat Program status

PrG.t Program time remaining in

hours
Li 2 Process value 2

rAt Ratio setpoint

PrG Selected program number

rSP Remote setpoint

LoG.L PV minimum

LoG.H PV maximum

LoG.A PV mean value

Log.t Time PV above Threshold level

Log.v PV Threshold for Timer Log

Continued in next column

Name Description

inFo Information list - continued

rES.L Logging Reset - ‘YES/no’

The following set of parameters is for
diagnostic purposes.

w.OP

Working output

FF.OP Feedforward component of output

VO

PID output to motorised valve


ACCS Access List

codE Access password

Goto Goto

level

-

OPEr, FuLL, Edit or

conF

ConF Configuration password