Thermcraft XST-6-0-36-3V User Manual
Page 117
Installation and Operation Handbook
Configuration
2408 and 2404 Controller
6-17
Name
Description
Values
Meaning
1A/b/C
(1)
Module 1 configuration
id
Identity of module installed
nonE
Module not fitted
rELy
Relay output
dC.OP
DC output isolated and non-
isolated
(1) If a dual-, or triple-, channel
LoG
Logic/PDS output
module is installed then the list
LoG.i
Logic input
headers
1b and 1C also appear
SSr
Triac output
dc.rE
DC retransmission (isolated)
dc.OP
Isolated DC output
SG.SU
Transducer power supply
For ‘
id’ = ‘rELy’, ‘LoG’, or ‘SSr’ use this parameter table:
Func
nonE
Function disabled
dIG
Digital output function
HEAt
Heating output
COOL
Cooling output
up
Open motorised valve
Function
(Only Channels
1A and 1C can be
Heating, or Cooling).
If a single logic output module is
fitted (code LO) this function will
need to be configured.
dwn
Close motorised valve
(Only if ‘
id’ = ‘LoG’) SSr.1
PDS mode 1 heating
(Only if ‘
id’ = ‘LoG’) SSr.2
PDS mode 2 heating
VAL.L
% PID demand signal giving
minimum output
− ‘Out.L’
VAL.H
% PID demand signal giving
maximum output
− ‘Out.H’
Out.L
Minimum average power
Out.H
Maximum average power
SEnS
Sense of output
(Only if ‘
Func’ = ‘dIG’)
nor
Normal (output energises
when TRUE, e.g program
events)
inv
Inverted (output de-energises
when TRUE, e.g. alarms)
Notes:
1. When
‘
SEnS’ appears, then further parameters are available. These are identical
to those in the ‘
AA ConF’ list on Page 6-14.
2. If a Tranducer Power Supply is fitted, the
SenS
parameter selects the output
voltage.
nor
= 5V,
inv
= 10V
3.
A Transducer Power Supply does not provide any calibration facility and is simply
a 5 or 10V power supply.
4. To invert a PID output, the Val. H can be set below the Val.L
f
VAL.L
Out.H
Out.L
VAL.H
PID Demand Signal
Electrical
Output