Installation and Operation Handbook

Configuration

2408 and 2404 Controller

6-3

LEAVING CONFIGURATION LEVEL

To leave the Configuration level and return to Operator level Press

until the ‘

Exit’

display appears.
Alternatively, pressing

and

together will take you directly to the ‘

Exit’ display.




Use

or

to select ‘

YES’. After a two-second

delay, the display will blank and revert to the Home
display in Operator level.

SELECTING A CONFIGURATION PARAMETER

The configuration parameters are arranged in lists as shown in the navigation diagram in
Figure 6.1.
To step through the list headers, press the Page

button.

To step through the parameters within a particular list press the Scroll

button.

When you reach the end of the list you will return to the list header.
You can return directly to the list header at any time by pressing the Page

button.

Parameter names

Each box in the navigation diagram shows the display for a particular parameter. The upper
readout shows the name of the parameter and the lower readout its value. For a definition of
each parameter, see the Configuration Parameter Tables at the end of this chapter. To change
the value of a selected parameter, use the

and

buttons.


The navigation diagram shows all the lists headers and parameters that can, potentially, be
present in the controller. In practice, those actually present will vary according to the
particular configuration choices you make.

CHANGING THE PASSWORDS

There are TWO passwords. These are stored in the Password configuration list and can be
selected and changed in the same manner as any other configuration parameter.
The password names are:

ACC.P’ which protects access to Full level and Edit level

cnF.P’ which protects access to Configuration level.