Thermcraft XST-6-0-36-3V User Manual
Page 137
Installation and Operation Handbook
Understanding The Ordering Code
2408 and 2404 Controller
A-3
Part 1B: Hardware coding
Plug-in
modules
Plug-in
modules
continued Module
2
Module
3
Alarm
relay
Comms
1
Comms
2
Manual
RC FL FH
YM TS ENG
* fitted unconfigured
Module 2
XX Not
fitted
Relay: 2-pin
R2 Fitted
unconfigured
RC Cooling
output
RW
Valve lower output
Relay: change-over
R4 Fitted
unconfigured
YC Cooling
Output
RL
Valve lower (note 6)
PO
Program event output 1
(note
7)
PE
Program END segment
Or Alarm 2: select from table A
Dual relay
RR Fitted
unconfigured
PP
Program events 1 & 2
(note 7)
Logic (non-isolated)
L2 Fitted
unconfigured
LC PID
cooling
Logic (isolated)
LO
Single logic output *
Triac
T2 Fitted
unconfigured
TC PID
cooling
TW
Valve lower output
DC control isolated
D4 Fitted
unconfigured
C6
0-20mA PID cooling
C7
4-20mA PID cooling
C8
0-5V PID cooling
C9
1-5V PID cooling
CZ
0-10V PID cooling
Digital I/O (unconfigured)
TK
Triple contact input
TL
Triple logic input
TP
Triple logic output
Power supply
MS 24Vdc
transmitter
DC retran (isolated)
Selct from table B
Potentiometer input
VU Fitted
unconfigured
VS
Valve position feedback
VR Setpoint
input
Transducer PSU
G3 5Vdc
G5 10Vdc
Comms 1
XX None
2-wire EIA-485
Y2 Fitted
unconfigured
YM Modbus
protocol
YE
EI Bisynch protocol
(note 1)
RS-232
A2 Fitted
unconfigured
AM Modbus
protocol
AE
EI Bisynch protocol
(note 1)
4-wire RS-485
F2 Fitted
unconfigured
FM Modbus
protocol
FE
EI Bisynch protocol
(note 1)
PDS output
M7 Fitted
unconfigured
PT PV
retransmission
TS Setpoint
retrans
OT Output
retrans
Profibus module
PB
High speed RS485
DeviceNet
DN DeviceNet
Comms 2
XX Not
fitted
PDS input
M6 Fitted
unconfigured
RS Setpoint
input
PDS output
M7 Fitted
unconfigured
PT PV
retransmission
TS Setpoint
retrans
OT Output
retrans
Module 3
XX Not
fitted
Relay: 2-pin
R2 Fitted
unconfigured
Relay: change-over
R4 Fitted
unconfigured
PO
Program event 4 (note
7)
PE
Program END output
Or Alarm 3 select from table A
Logic (non-isolated)
L2 Fitted
unconfigured
Logic (isolated)
LO
Single logic output
*
Triac
T2 Fitted
unconfigured
Dual relay
RR Fitted
unconfigured
PP
Program event 4 & 5
(note 7)
Digital I/O (unconfigured)
TK
Triple contact input
TL
Triple logic input
TP
Triple logic output
Power supply
MS 24V
transmitter
DC remote input
D5 Fitted
unconfigured
W2
4 to 20mA setpoint
W5
0 to 10V setpoint
WP
Second PV input
DC retran (isolated)
Select from table B
Potentiometer input
VU Fitted
unconfigured
VS VP
feedback
VR Setpoint
input
Transducer PSU
G3 5Vdc
G5 10Vdc
Manual
XXX No
manual
ENG English
FRA French
GER German
NED Dutch
SPA Spanish
SWE Swedish
ITA Italian
Alarm relay
XX Not
fitted
Alarm 4 relay
RF
Fitted unconfigured
Table A alarm options plus:
RA
Rate of change
PDS alarms
LF
Heater break detect
HF
Current monitor heater brk
SF
Current monitor SSR fail
PO
Program event 7 (note 7)
PE
Program END output