Installation and Operation Handbook

Understanding The Ordering Code

2408 and 2404 Controller

A-3

Part 1B: Hardware coding

Plug-in

modules

Plug-in

modules

continued Module

2

Module

3

Alarm

relay

Comms

1

Comms

2

Manual

RC FL FH

YM TS ENG


































* fitted unconfigured

Module 2

XX Not

fitted

Relay: 2-pin
R2 Fitted

unconfigured

RC Cooling

output

RW

Valve lower output

Relay: change-over
R4 Fitted

unconfigured

YC Cooling

Output

RL

Valve lower (note 6)

PO

Program event output 1

(note

7)

PE

Program END segment

Or Alarm 2: select from table A
Dual relay
RR Fitted

unconfigured

PP

Program events 1 & 2
(note 7)

Logic (non-isolated)
L2 Fitted

unconfigured

LC PID

cooling

Logic (isolated)
LO

Single logic output *

Triac
T2 Fitted

unconfigured

TC PID

cooling

TW

Valve lower output

DC control isolated
D4 Fitted

unconfigured

C6

0-20mA PID cooling

C7

4-20mA PID cooling

C8

0-5V PID cooling

C9

1-5V PID cooling

CZ

0-10V PID cooling

Digital I/O (unconfigured)
TK

Triple contact input

TL

Triple logic input

TP

Triple logic output

Power supply
MS 24Vdc

transmitter

DC retran (isolated)
Selct from table B
Potentiometer input
VU Fitted

unconfigured

VS

Valve position feedback

VR Setpoint

input

Transducer PSU
G3 5Vdc
G5 10Vdc

Comms 1

XX None
2-wire EIA-485
Y2 Fitted

unconfigured

YM Modbus

protocol

YE

EI Bisynch protocol
(note 1)

RS-232
A2 Fitted

unconfigured

AM Modbus

protocol

AE

EI Bisynch protocol
(note 1)

4-wire RS-485
F2 Fitted

unconfigured

FM Modbus

protocol

FE

EI Bisynch protocol
(note 1)

PDS output
M7 Fitted

unconfigured

PT PV

retransmission

TS Setpoint

retrans

OT Output

retrans

Profibus module
PB

High speed RS485

DeviceNet
DN DeviceNet

Comms 2

XX Not

fitted

PDS input
M6 Fitted

unconfigured

RS Setpoint

input

PDS output
M7 Fitted

unconfigured

PT PV

retransmission

TS Setpoint

retrans

OT Output

retrans

Module 3

XX Not

fitted

Relay: 2-pin
R2 Fitted

unconfigured

Relay: change-over
R4 Fitted

unconfigured

PO

Program event 4 (note
7)

PE

Program END output

Or Alarm 3 select from table A
Logic (non-isolated)

L2 Fitted

unconfigured

Logic (isolated)
LO

Single logic output

*

Triac

T2 Fitted

unconfigured

Dual relay

RR Fitted

unconfigured

PP

Program event 4 & 5
(note 7)

Digital I/O (unconfigured)
TK

Triple contact input

TL

Triple logic input

TP

Triple logic output

Power supply
MS 24V

transmitter

DC remote input
D5 Fitted

unconfigured

W2

4 to 20mA setpoint

W5

0 to 10V setpoint

WP

Second PV input

DC retran (isolated)
Select from table B
Potentiometer input
VU Fitted

unconfigured

VS VP

feedback

VR Setpoint

input

Transducer PSU
G3 5Vdc
G5 10Vdc

Manual

XXX No

manual

ENG English
FRA French
GER German
NED Dutch
SPA Spanish
SWE Swedish
ITA Italian

Alarm relay

XX Not

fitted

Alarm 4 relay
RF

Fitted unconfigured

Table A alarm options plus:
RA

Rate of change

PDS alarms
LF

Heater break detect

HF

Current monitor heater brk

SF

Current monitor SSR fail

PO

Program event 7 (note 7)

PE

Program END output