2408 and 2404 Controller

Profibus-DP is a multimaster, master-slave, token passing network. The 2408f and the 2404f
operate as intelligent slave units. More detailed information, including a detailed guide to
products available, may be obtained from the various world wide Profibus user organisations.
You will find contact information in trade magazines or by reference to
http://www.profibus.com on the World Wide Web.

Technical Specification

Physical Medium

2-wire RS485

Network topology

Linear bus with active termination of the bus at both ends

Stub lines permitted if < 6.6m in length

Protocol

Profibus-DP,

intelligent

slave

Baud rate

Up to 1.5Mb/s

Number of stations

32 per network segment. Up to 127 with repeaters

Electrical Connections
The diagram below is also shown in Chapter 1.
























SHIELD

Station 1

HA

HB

HC

HD

HE

HF

Shield

VP (+5Vdc Voltage Potential)

B (Rx/Tx +ve)

A (Rx/Tx -ve)

DGND (Digital ground)

Not connected

B

390

Ω

Last Station

HA

HB

HC

HD

HE

HF

Shield

VP (+5Vdc Voltage Potential)

B (Rx/Tx +ve)

A (Rx/Tx -ve)

DGND (Digital ground)

Not connected

Intermediate stations

Last station only requires
terminating resistors

390

Ω

220

Ω

A

B

A

B

A

2408f or 2404f controller

2408f or 2404f controller

Twisted

pair

Twisted

pair