2098-ipd-hv030 – Rockwell Automation 2098-IPD-xxx Ultra5000 Intelligent Positioning Drives Installation Manual User Manual
Page 99

Publication 2098-IN001E-EN-P — April 2002
Specifications and Dimensions
A-3
2098-IPD-HV030-xx, -HV050-xx, -HV100-xx, -HV150-xx, and
-HV220-xx
The table below lists general power specifications and requirements
for the Ultra5000 460V drives.
Specification
Description
2098-IPD-HV030
and
2098-IPD-HV030-DN
2098-IPD-HV050
and
2098-IPD-HV050-DN
2098-IPD-HV100
and
2098-IPD-HV100-DN
2098-IPD-HV150
and
2098-IPD-HV150-DN
2098-IPD-HV220
and
2098-IPD-HV220-DN
AC Input Voltage
1, 2
230-480V
rms
Three Phase
AC Input Frequency
47 - 63 Hz
Main AC Input Current
3
Nominal, 460V ac input
Maximum inrush, 460V ac input
4A
rms
6A
rms
7A
rms
6A
rms
14A
rms
6A
rms
20A
rms
6A
rms
28A
rms
6A
rms
Auxiliary AC Input Current
Nominal, 230V ac input
Nominal, 360V ac input
Nominal, 480V ac input
Maximum inrush, 230V ac input
4
Maximum inrush, 480V ac input
4
0.55A
rms
0.35A
rms
0.25A
rms
47A (0-peak)
68A (0-peak)
0.55A
rms
0.35A
rms
0.25A
rms
47A (0-peak)
68A (0-peak)
0.55A
rms
0.35A
rms
0.25A
rms
47A (0-peak)
68A (0-peak)
0.55A
rms
0.35A
rms
0.25A
rms
47A (0-peak)
68A (0-peak)
0.55A
rms
0.35A
rms
0.25A
rms
47A (0-peak)
68A (0-peak)
Continuous Output Current
7A (0-peak)
11A (0-peak)
23A (0-peak)
34A (0-peak)
47A (0-peak)
Intermittent Output Current
14A (0-peak)
22A (0-peak)
46A (0-peak)
68A (0-peak)
94A (0-peak)
Internal Shunt
Continuous power
Peak power
100W
5.3 kW
100W
5.3 kW
200W
16 kW
200W
25.6 kW
400W
32 kW
External Shunt
Minimum resistance
Continuous power
Peak power
120 Ohms
3 kW
5.3 kW
120 Ohms
5 kW
5.3 kW
40 Ohms
10 kW
16 kW
25 Ohms
15 kW
25.6 kW
20 Ohms
22 kW
32 kW
Energy Absorption Capability
230V ac input with 230V motor
230V ac input with 460V motor
460V ac input
58 Joules
517 Joules
219 Joules
58 Joules
517 Joules
219 Joules
88Joules
776Joules
329 Joules
117 Joules
1034 Joules
439 Joules
234 Joules
2069 Joules
878Joules
Continuous Power Output
230V ac input
460V ac input
1.5 kW
3.0 kW
2.5 kW
5.0 kW
5.0 kW
10 kW
7.5 kW
15 kW
11 kW
22 kW
1
Specification is for nominal voltage. The absolute limits are ±10%, or 207-528V
rms
.
2
3
The 2098-HV
xxx -xx (460V) drives are limited to three contactor cycles per minute.
4
400
μs half wave sine, inrush current is processor controlled via soft start circuitry.