Publication 2098-IN001E-EN-P — April 2002
A-2
Specifications and Dimensions
2098-IPD-030-xx, -075-xx, and -150-xx
The table below lists general power specifications and requirements
for the Ultra5000 230V drives.
Specification
Description
2098-IPD-030,
2098-IPD-030-DN
2098-IPD-075,
2098-IPD-075-DN
2098-IPD-150,
2098-IPD-150-DN
AC Input Voltage
1
100-240V
rms
Single Phase
100-240V
rms
Three Phase
AC Input Frequency
47 - 63 Hz
Main AC Input Curren
t
2
Nominal,
Maximum inrush, 230V ac input
28A
rms
50A
rms
30A
rms
50A
rms
46A
rms
68A
rms
Auxiliary AC Input Current
Nominal, 115V ac input
Nominal, 230V ac input
Maximum inrush, 115V ac input
3
Maximum inrush, 230V ac input
3
1.0A
rms
0.5A
rms
47A (0-peak)
95A (0-peak)
1.0A
rms
0.5A
rms
47A (0-peak)
95A (0-peak)
1.0A
rms
0.5A
rms
47A (0-peak)
95A (0-peak)
Continuous Output Current
15A (0-peak)
35A (0-peak)
65A (0-peak)
Intermittent Output Current
30A (0-peak)
75A (0-peak)
150A (0-peak)
Internal Shunt
Continuous power
Peak power
50W
4.5 kW
50W
10 kW
180W
18 kW
External Shunt
Minimum resistance
Continuous power
Peak power
30 Ohms
2.4 kW
6 kW
16.5 Ohms
4 kW
10 kW
9 Ohms
8 kW
19 kW
Energy Absorption Capability
115V ac input
230V ac input
203 Joules
96 Joules
321 Joules
151 Joules
563 Joules
265 Joules
Continuous Power Output
115V ac input
230V ac input
1.5 kW
3 kW
3.75 kW
7.5 kW
7.5 kW
15 kW
1
Specification is for nominal voltage. The absolute limits are ±10%, or 88-265V
rms
.
2
The 2098-030-
xx, -075-xx, and -150-xx (230V) drives are limited to two contactor cycles per minute.
3
400
μs half wave sine, inrush current is processor controlled via soft start circuitry.