Troubleshooting for devicenet drives, Devicenet module status led, Troubleshooting for devicenet drives -6 – Rockwell Automation 2098-IPD-xxx Ultra5000 Intelligent Positioning Drives Installation Manual User Manual
Page 92: Devicenet module status led -6
Publication 2098-IN001E-EN-P — April 2002
5-6
Maintaining Your Ultra5000
Troubleshooting for
DeviceNet Drives
DeviceNet Module Status LED
Use the table below for troubleshooting the DeviceNet Module Status
LED on your Ultra5000 (2098-IPD-xxx-DN, or -HVxxx-DN).
37
AC Line Loss
One or more phases of the input AC
power is missing.
Check input AC voltage on all phases.
38
Reserved
Call your local Allen-Bradley
representative.
39
Self-sensing Commutation Startup
Error
Motion required for self-sensing
startup commutation was obstructed.
• Verify that there are no
impediments to motion at startup,
such as hard limits.
• Increase self-sensing current if high
friction or load conditions exist.
• Check motor or encoder wiring
using wiring diagnostics.
40 - 57
Reserved
Call your local Allen-Bradley
representative.
58
Excess CPU Load
User function(s) inserted into
sequencer take too much time.
Remove user function from sequencer
or reduce size of user function.
59 - 99
Reserved
Call your local Allen-Bradley
representative.
Error
Code
Problem or Symptom
Possible Cause(s)
Action/Solution
If the Module
Status LED is:
Status is:
Potential Cause is: Possible Resolution is:
Off
Not powered
No power
There is no power going to the device.
Steady-Green
Operational
Normal operation
Normal operation - no action needed.
Flashing-Green
Device is in
stand-by
Processing or waiting
for input
Normal operation - no action needed.
Flashing-Red
Recoverable
fault
Not operational
Power cycle or reset the drive.
Steady-Red
Unrecoverable
fault
Drive problem
Check drive for power-up error.
Replace drive.
Flashing-Red/
Green
Self testing
Self-test in progress
The device is in self test, wait.