beautypg.com

Troubleshooting for devicenet drives, Devicenet module status led, Troubleshooting for devicenet drives -6 – Rockwell Automation 2098-IPD-xxx Ultra5000 Intelligent Positioning Drives Installation Manual User Manual

Page 92: Devicenet module status led -6

background image

Publication 2098-IN001E-EN-P — April 2002

5-6

Maintaining Your Ultra5000

Troubleshooting for

DeviceNet Drives

DeviceNet Module Status LED

Use the table below for troubleshooting the DeviceNet Module Status
LED on your Ultra5000 (2098-IPD-xxx-DN, or -HVxxx-DN).

37

AC Line Loss

One or more phases of the input AC
power is missing.

Check input AC voltage on all phases.

38

Reserved

Call your local Allen-Bradley
representative.

39

Self-sensing Commutation Startup
Error

Motion required for self-sensing
startup commutation was obstructed.

• Verify that there are no

impediments to motion at startup,
such as hard limits.

• Increase self-sensing current if high

friction or load conditions exist.

• Check motor or encoder wiring

using wiring diagnostics.

40 - 57

Reserved

Call your local Allen-Bradley
representative.

58

Excess CPU Load

User function(s) inserted into
sequencer take too much time.

Remove user function from sequencer
or reduce size of user function.

59 - 99

Reserved

Call your local Allen-Bradley
representative.

Error

Code

Problem or Symptom

Possible Cause(s)

Action/Solution

If the Module

Status LED is:

Status is:

Potential Cause is: Possible Resolution is:

Off

Not powered

No power

There is no power going to the device.

Steady-Green

Operational

Normal operation

Normal operation - no action needed.

Flashing-Green

Device is in
stand-by

Processing or waiting
for input

Normal operation - no action needed.

Flashing-Red

Recoverable
fault

Not operational

Power cycle or reset the drive.

Steady-Red

Unrecoverable
fault

Drive problem

Check drive for power-up error.
Replace drive.

Flashing-Red/
Green

Self testing

Self-test in progress

The device is in self test, wait.