INFICON Cygnus Thin Film Deposition Controller User Manual
Page 126

5 - 22
IP
N 07
4-
37
9-
P1
K
Cygnus Operating Manual
shows Action Codes in HEX notation.
"s" indicates Channel number: 0 to 6
"n" indicates Channel number: 1 to 6
Maximum Pwr s
Maximum Power s
0x57
0xA9
Minimum Pwr s
Minimum Power s
0x58
0xA8
Thick Sum x xxx.xxx
Thickness Sum x xxx.xxx
(x = 1 to 3, equation number
from general parameters;
xxx.xxx = 0 to 999.9 kÅ)
see note 1
0x59
0xA7
NOTE 1: Thickness Limit and Thickness Sum will be sent as an integer Angstroms
(the number here *1000)
NOTE 2: Timer Limit HH:MM second numeric will be sent as
an integer number of minutes.
NOTE 3: Timer Limit Sec value will be sent as an integer tenth of seconds.
Table 5-7 Action Codes
Name
Description
Code
External Out On x
Set External Output x (x = 1 to 38)
0x41
External Out Off x
Clear External Output x (x = 1 to 38)
0x42
Start n
Start (Go to Pre-Dep) n
0x43
Stop s
Stop (Idle at Power = 0) s
0x44
Reset s
Reset s
0x45
Zero Thick s
Zero Thickness s
0x46
Switch Xtal n
Switch Crystal n
0x47
Clock Hold On n
Non-Rate Control Clock Hold On n
0x48
Clock Hold Off n
Non-Rate Control Clock Hold Off n
0x49
Xtl Fl Inhibit On s
Crystal Fail Inhibit On s
0x4A
Xtl Fl Inhibit Off s
Crystal Fail Inhibit Off s
0x4B
Start Timer x
(Re)Start Timer x (set timer to zero
and start incrementing) (x = 1 to 20)
0x4C
Cancel Timer x
Cancel Timer x (set timer to zero and
don’t increment) (x = 1 to 20)
0x4D
Clear Counter x
Clear Counter x (x = 1 to 20)
0x4E
Table 5-6 Event Codes (continued)
Name
Description
Normal
Negated