Toshiba Magnia 3310 User Manual
Page 34
Getting Started
Front view (with the front doors opened)
15
*1 About the lighting (in amber) of the fan and power unit fault indicators, see
“Indication in case of the occurrence of an EPS-R module failure or cooling
fan module failure” described below.
NOTE: If any trouble has occurred, contact an authorized
MAGNIA service provider.
Indicator
Status
Meaning
Power
Off
Out of operation (AC power not supplied)
Lit amber Out of operation (AC power supplied)
Lit green In operation
Disk
Off
One of the following modes:
- Out of operation (AC power supplied/not supplied)
- Disk drive out of operation
Flashing
amber
Disk array being rebuilt
(Valid only when the RAID controller is in use.)
Lit amber Disk failure occurred
(Valid only when the RAID controller is in use.)
Flashing
green
Disk drive in operation
(For models without a RAID controller, this indicator
also flashes green when another SCSI device
connected to the onboard SCSI controller is running.)
Fan fault
Off
One of the following modes:
- Out of operation (AC power supplied/not supplied)
- The cooling fan is operating normally.
Lit amber - The cooling fan is faulty. *1
Power
unit fault
Off
One of the following modes:
- Out of operation (AC power supplied/not supplied)
- The power supply unit is operating normally.
Lit amber The power supply unit is faulty. *1