beautypg.com

Allied Telesis AT-S60 User Manual

Page 99

background image

AT-S60 Command Line User’s Guide

97

Note

The selections 10mfauto, 100mhauto, 100mfauto, and 1000mfauto
cause a port to Auto-Negotiate to a lower speed and/or to half
duplex mode if required by the end node.

priority

Specifies the port’s priority. Settings for this

parameter are:

nooverride

A tagged frame’s priority is

determined by its tagged header. This
is the default setting.

lowpriority

Tagged frames and untagged frames
received on the port are directed to
the low priority egress queue.

highpriority

All tagged frames and untagged

frames received on the port are
directed to the high priority egress
queue.

Description

This command sets a port’s operating parameters. You can set more
than one parameter at a time with this command. For an explanation of
the port parameters, refer to the AT-S60 Management Software User’s
Guide
.

Examples

The following command configures Port 8 on the line card in Slot 2 to
operate at 10 Mbps, half duplex:

set switch port=2.8 speed=10mhalf

The following command sets the wiring configuration to MDI-X and
disables flow control for Ports 2 through 6 on the line card in Slot 4:

set switch port=4.2-6 mdimode=mdix
flowcontrol=disable

The following command disables Ports 1 through 6 on the line card in
Slot 7:

set switch port=7.1-6 status=disabled