Set system – Allied Telesis AT-S60 User Manual
Page 50
Chapter 3: Basic Switch Commands
48
SET SYSTEM
Syntax
set system [name=”name”] [contact=”contact”]
[location=”location”]
Parameters
The parameters are defined below:
name
Specifies the name of the switch. The name can be from 1 to
15 alphanumeric characters in length and must be enclosed
in quotes (“ “). Spaces are permitted.
contact
Specifies the name of the network administrator
responsible for managing the switch. This field can be from
1 to 15 alphanumeric characters in length and must be
enclosed in quotes (“ “). Spaces are permitted.
location
Specifies the location of the switch. The location of a switch
is often a building and room number. The location can be
from 1 to 15 alphanumeric characters in length and must be
enclosed in quotes (“ “). Spaces are permitted.
Description
This command sets a switch’s name, the name of the network
administrator responsible for managing the unit, and the location of the
unit.
If one of the above parameters already has a value, the new value
replaces the existing value. If you want to delete an existing name,
contact, or location value without assigning a new value, refer to RESET
SYSTEM on page 38.
Examples
The following command sets the system name to Sales, the contact to
Jane Smith, and the location to Bldg 3, rm 212:
set system name=”Sales” contact=”Jane Smith”
location “Bldg 3, rm 212”
The following command sets the system name to PR Office:
set system name=”PR Office”