beautypg.com

Set switch stackmode – Allied Telesis AT-S60 User Manual

Page 93

background image

AT-S60 Command Line User’s Guide

91

SET SWITCH STACKMODE

Syntax

set switch stackmode=[master|slave|unavailable]

Parameter

stackmode

Specifies the enhanced stacking mode of the switch.
Possible settings are:

master

Specifies the switch’s stacking
mode as master. A master switch
must be assigned an IP address and
subnet mask.

slave

Specifies the switch’s stacking
mode as slave. A slave does not
need an IP address. This is the
default setting for a switch.

unavailable

Specifies the switch’s stacking
mode as unavailable. A switch with
this status cannot be managed from
an enhanced stack. It can be
managed locally through its RS-232
Terminal Port or remotely if it is
assigned an IP address and subnet
mask.

Description

This command sets a switch’s enhanced stacking status.

Note

To determine the master or slave status of a switch, use SHOW
SWITCH
on page 55.

Example

The following command sets the switch’s stacking status to master:

set switch stackmode=master