Advanced Configuration Commands
202
sdvars set
setactivepointer
s
Purpose
Sets the setactivepointers command to change inactive segments to
active segments the next time the access point is rebooted. This
command is usually used with the nextpoweruptime command.
Syntax
sdvars set setactivepointers none/boot/data/both
where:
none
does not change the active segments. The
default is none. Also, when the reboot is
completed, the access point resets this
value to none.
boot
changes the inactive boot segment to the
active boot segment.
data
changes the inactive data segment to the
active data segment.
both
changes both the boot and data inactive
segments to the active segments.
Example
To change the inactive boot and data segments to active at the next
reboot, enter:
sdvars set setactivepointers both
sdvars set
nextpowerupti
me
Purpose
Sets the nextpoweruptime command to set the internal variable
nextpoweruptime to a countdown time so that when 0 is reached, the
access point will reboot. When the nextpoweruptime counter reaches 0,
the access point checks the value of the setactivepointers variable, takes
the appropriate action, and then reboots.
Syntax
sdvars set nextpoweruptime dd:hh:mm:ss
where dd:hh:mm:ss is how far in the future the reboot is to begin.