167

6.

Scroll up on the communications software window until you see a
section similar to the following:

Startup Segment:

This startup = 1,

Next startup = 1

Data Segment:

This startup = 3,

Next startup = 3

7.

These are the current startup and data segments. In this example,
the active startup segment is 1 and the active data segment is 3.

You will first erase the inactive segments and then you will load the
new firmware into the inactive segments and make those segments
active. In this example, the inactive segments are 2 and 4.

8.

Erase the inactive startup segment. Type fe 2 at the service>
prompt and press . A P appears in the command line when
the segment is erased.

9.

Erase the inactive data segment. Type fe 4 at the service> prompt
and press . A P appears in the command line when the
segment is erased.

10. Transfer the startup files to the inactive startup segment.

a.

At the service> prompt, type fx s (where s is the inactive startup
segment) and press . A series of Cs appears in the
command line.

b.

Select the Transfer Menu tab in your communications
program then select Send File. The Send File dialog box as
shown in Figure 65 is displayed.

Figure 65 Send File

c.

Select the Protocol down arrow and choose Ymodem.

d.

Browse to the location where the UAP.DNL is saved. Double-
click this file so that it appears in the Filename field.

e.

Select Send to start the file transfer. A P appears in the
command line when the transfer is complete.