beautypg.com

System set port – Allied Telesis AT-S97 User Manual

Page 89

background image

AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide

89

SYSTEM SET PORT

Syntax

system set port id=

c

/

m

|

b/

[

pp

]/[

port

]

port-state=disable|enable auto-neg=disable|enable
speed=10|100|1000 duplex=half|full
crossover=mdi|mdix
ingress-rate-limit=none|128k|256k|512k|1m|2M|4M|8M
egress-rate-limit=none|128k|256k|512k|1m|2M|4M|8M

Parameters

id

Specifies a twisted pair or fiber optic port on a media

converter module. You can configure one port at a time, all
the ports of the same type (that is, twisted pair or fiber optic
ports), one port pair, and all of the ports on a module. The
ID consists of the following parts:

c

Identifies the ID number of the chassis. The
chassis ID number depends on which module is
installed in the management slot of the chassis.
When a management module is installed in this
slot, the chassis ID number is 0 or 31. When a
stacking module is installed in this slot, the
chassis ID can be from 1 to 30.

m

Specifies the 10/100/100Base-T port on the
management module.

b

Specifies a slot number of a media converter
slot. In the AT-MCF2000 Chassis, the left slot is
1 and the right slot is 2.

pp

Specifies the number of the channel on the
AT-MCF2012LC and AT-MCF2012LC/1
Modules with the port to be configured. To
configure all the ports of the same type, either
twisted pair or fiber optic ports, omit this
parameter. Possible values are:

1 to 12

Specifies a channel. Channel 1
consists of twisted pair port 1 and
fiber topic port 1, channel 2 of twisted
pair port 2 and fiber topic port 2, and
so on. You can specify only one
channel.

This manual is related to the following products: