AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide

137

Stacking Port Link

A Stack port on the management module or
the AT-MCF2000S Stacking Module
established or lost its link to another Stack
port.

Report

Major Level Messages

Chassis Managership
Acquire

A media converter module has acquired the
second priority to the CMN_Grant which
allows access to the I2C bus.

Report

Chassis Managership
Release

A media converter module has released the
second priority to the CMN_Grant.

Report

Chassis Reset

The chassis was reset with the SYSTEM
RESET CHASSIS command.

Report

Cold Boot

A media converter module loaded its boot
loader and management software after
receiving power. It generates this message
when the chassis is powered on or if it is
installed while a unit is powered on.

Report

Fan # Failure

A cooling fan in a power supply or fan
module stopped.

Report

A cooling fan resumed operating after having
stopped.

Clear

High Temperature
Threshold

A module’s operating temperature exceeded
the temperature threshold set with the
SYSTEM SET MODULE command.

Report

A module’s operating temperature returned
below its temperature threshold.

Clear

Module Reset

A media converter module started the
process of initializing its boot loader and
AT-S85 Management Software after it was
reset with the SYSTEM RESET MODULE
command. The completion of the initialization
process is signaled with the Warm Boot
message.

Report

Warm Boot

A media converter module completed the
initialization of its management software after
being reset with the SYSTEM RESET
MODULE command.

Report

Table 11. Event Messages (Continued)

Message

Definition

Classification