SYSTEM RESET CHASSIS
Syntax
system reset chassis id=
chassis
Parameters
id
Identifies the ID number of the chassis to reset. To view a
unit’s ID number, use the SYSTEM SHOW CLUSTER
command. For instructions, see “SYSTEM SHOW
CLUSTER” on page 99.
Privilege Levels
Administrator and read-write.
Description
This command resets all the modules, both media converter modules and
the management module, in a chassis by initializing the modules’ AT-S85
and AT-S97 Management Software. You might reset a chassis if you are
experiencing a problem with its modules.
Note
Resetting a media converter module may result in the loss of some
network traffic.
Note
When reset, the management module is unresponsive to commands
for approximately one minute while it initializes the AT-S97
Management Software.
Note
When reset, a media converter module immediately resumes
forwarding network traffic through its ports and channels using its
default settings while it initializes its AT-S85 Management Software,
a process that takes approximately one minute to complete. The
module is unresponsive to management commands during the
initialization process. At the completion of the process, the module
configures its ports and channels according to the settings in the
active master configuration file on the management module.