Config run – Allied Telesis AT-S97 User Manual
Page 155

AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide
155
CONFIG RUN
Syntax
config run
Parameters
None.
Privilege Levels
Administrator and read-write.
Description
This command configures the parameters settings on the modules in the
chassis according to the settings in the active master configuration file on
the management module. This command is typically used to configure the
modules after you have designated a new active master configuration file
on the management module. Here is the sequence of the commands to
perform this function:
1. Designate a new active master configuration file for the chassis using
the CONFIG SET command. For instructions, refer to “CONFIG SET”
on page 160.
2. Configure the settings on the modules according to the settings in the
file by performing this command.
This command is also useful if you configured the parameters of the
modules but did not save them, and want to discard the changes and
return to the original configuration of the modules. For example, perhaps
you modified but did not save the settings of the ports on a media
converter module, and want to discard the changes.
The result of the CONFIG RUN command is similar to the SYSTEM
RESET CHASSIS command or power cycling the unit. The difference is
that with the CONFIG RUN command the management software on the
modules is not initialized which makes for a faster reset and configuration
of the modules. A reset or a power cycle of a chassis can take upwards of
one minute to complete while the modules initialize their management
software. The CONFIG RUN command is much faster and is typically
completed in just a few seconds.