System set asynchronous – Allied Telesis AT-S97 User Manual
Page 58

Chapter 5: General System Commands
58
SYSTEM SET ASYNCHRONOUS
Syntax
system set asynchronous baudrate=2400|4800|9600|19200|115200
Parameters
baudrate
Sets the baud rate of the RS-232 Terminal port on the
AT-MCF2000M Management Module. The default is
115,200 bits per second (bps).
Privilege Levels
Administrator and read-write.
Description
This command sets the baud rate of the RS-232 Terminal port on the
AT-MCF2000M Management Module. This port is used for local
management of the chassis. To view the port’s current baud rate setting,
refer to “SYSTEM SHOW ASYNCHRONOUS” on page 65.
Note
Changing the baud rate of the RS-232 Terminal port on the
management module during a local management session ends the
session. To resume managing the module, change the speed of the
terminal or the terminal emulator program to the new speed of the
RS-232 Terminal port.
The other settings of the RS-232 Terminal port listed here are not
adjustable:
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Example
This command sets the baud rate of the RS-232 Terminal port to 2,400
bps:
system set asynchronous baudrate=2400