Description
This command displays status information about the media converter,
power supply, fan, and management modules in a chassis. The
information varies depending on the module. Figure 16 is an example of
the information for the AT-MCF2000AC Power Supply Module or the
AT-MCF2KFAN Fan Module.
Figure 16. SYSTEM SHOW MODULE Command for a Power Supply or
Fan Module
The acronym “RPS” for “Redundant Power Supply” in the top line should
be ignored. It is a misnomer for a fan module as well as for a power supply
module in a chassis with one power supply. The letter following “RPS” is
the chassis slot location of the power supply or fan module.
RPSA Information:
Module Name ................
Module Type ................ AT-MCF2000AC
Power OK ................... Yes
Module Present ............. Present
3.3V ....................... Good = 3.415V
12.0V ...................... Good = 12.125V
Temperature ................ 25.821 C
Temperature Threshold ...... 60 C
Fan A Speed ................ 7105 RPM
Fan B Speed ................ 7033 RPM