Chapter 1: Starting a Command Line Management Session

20

Starting a Local Management Session

Note

Local management sessions do not require an IP configuration on
the AT-MCF2000M Management Module.

To start a local management session on the chassis, perform the following
procedure:

1. Connect the DIN-8 connector on the RS-232 Serial Management

Cable included with the AT-MCF2000M Management Module to the
RS-232 Terminal port on the module, as shown in Figure 2.

Figure 2. Connecting the RS-232 Serial Management Cable to the RS-232

Terminal Port

2. Connect the other end of the cable to an RS-232 port on a terminal or

PC with a terminal emulator program.

3. Configure the terminal or terminal emulation program as follows:

ˆ

Baud rate: 115,200 bps (The RS-232 Terminal port has a baud
rate range of 9600 to 115,200 bps. The default is 115,200 bps. To
adjust the baud rate, refer to “SYSTEM SET ASYNCHRONOUS”
on page 58.)

ˆ

Data bits: 8

ˆ

Parity: None

ˆ

Stop bits: 1

ˆ

Flow control: None

Note

The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.

1261

AT-MCF

2000

M

STACK

MANAG

EMEN

T

TERM

INAL

10/100/1000

BASE-T

RS-232

RES

ET

SD

RDY

BUSY

MASTE

R

POWER

BOOT

RDY

FAULT

1000 L

INK

ACT

10/100

LINK

ACT

FDX

HDX

COL

LINK

ACT

POR

T ACTIV

ITY

0

31

ID

AT-MCF2KF

AN

NORM

AL

FAULT

STATUS

This manual is related to the following products: