Starting a local management session, Data bits: 8, Parity: none – Allied Telesis AT-S97 User Manual
Page 20: Stop bits: 1, Rdy busy, Boot rdy fault
Chapter 1: Starting a Command Line Management Session
20
Starting a Local Management Session
Note
Local management sessions do not require an IP configuration on
the AT-MCF2000M Management Module.
To start a local management session on the chassis, perform the following
procedure:
1. Connect the DIN-8 connector on the RS-232 Serial Management
Cable included with the AT-MCF2000M Management Module to the
RS-232 Terminal port on the module, as shown in Figure 2.
Figure 2. Connecting the RS-232 Serial Management Cable to the RS-232
Terminal Port
2. Connect the other end of the cable to an RS-232 port on a terminal or
PC with a terminal emulator program.
3. Configure the terminal or terminal emulation program as follows:
Baud rate: 115,200 bps (The RS-232 Terminal port has a baud
rate range of 9600 to 115,200 bps. The default is 115,200 bps. To
adjust the baud rate, refer to “SYSTEM SET ASYNCHRONOUS”
on page 58.)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.