System show module – Allied Telesis AT-S97 User Manual
Page 108

Chapter 6: Port and Module Commands
108
SYSTEM SHOW MODULE
Syntax
system show module id=
chassis
/
slot
Parameters
id
Identifies a module. You can specify only one module at a
time. The ID number consists of the following parts:
chassis
Identifies the ID number of the chassis. The
chassis ID number depends on which module is
installed in the management slot of the chassis.
When a management module is installed in this
slot, the chassis ID number is 0 or 31. When a
stacking module is installed in this slot, the
chassis ID can be from 1 to 30.
slot
Specifies the ID number or letter of the slot with
the module. Possible values are:
m
Specifies the management module
slot. This slot is used for the
management module or the stacking
module.
a or b
Specifies a slot letter of a power
supply or fan module. In the
AT-MCF2000 Chassis, the left slot is
A and the right slot is B when the unit
is viewed from the back.
1 or 2
Specifies a slot number of a media
converter module. In the
AT-MCF2000 Chassis, the left slot is
1 and the right slot is 2 when the unit
is viewed from the front.
To view the ID and slot numbers of a chassis, refer to
“SYSTEM SHOW CLUSTER” on page 99 or “SYSTEM
SHOW CHASSIS” on page 96.
Privilege Levels
Administrator, read-write, and read-only.