Diagnostics show chassis, Figure 43: diagnostics show chassis eeprom command – Allied Telesis AT-S97 User Manual
Page 229

AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide
229
DIAGNOSTICS SHOW CHASSIS
Syntax
diagnostics show chassis id=
chassis
eeprom
Parameters
id
Identifies the ID number of a chassis. The range of chassis
ID numbers is from 0 to 31. To display a unit’s ID number,
use the SYSTEM SHOW CLUSTER command. For
instructions, see “SYSTEM SHOW CLUSTER” on page 99.
eeprom
Displays the serial numbers, hardware revision levels, and
MAC addresses of the modules.
Privilege Levels
Administrator, read-write, and read-only.
Description
This command displays manufacturing information about the modules in
the chassis. If you contact Allied Telesis Technical Support for assistance,
you need to provide this information.
Figure 43. DIAGNOSTICS SHOW CHASSIS EEPROM Command
The fields are defined here:
Slot ID: A slot in the chassis. Possible values are:
– C: Indicates the chassis.
– M: Indicates the management slot for the
AT-MCF2000M Management Module.
– number: A media converter slot number (for example,
1, 2, etc.). Empty slots are not included in the tables.
Slot Module
Module
Serial
HW
MAC
ID
Name
Type
Number
Rev
Address
----------------------------------------------------------------------
C
AT-MCF2000
4
X1
00:15:77:70:7A:2A
M
AT-MCF2000M A03678L072000005A
A
00:15:77:70:7A:2B
1
AT-MCF2012LC
20 yyyy
00:15:77:70:7A:2F
2
AT-MCF2012LC
14 yyyy
00:15:77:70:7A:22
A
AT-MCF2KFAN
8 yyyy
B
AT-MCF2000AC
A0367G070400086B
B