beautypg.com

Viewing the drive cage magazine details – HP 3PAR Operating System Software User Manual

Page 81

background image

The following information for DC1 drive cages is provided:

Description

Column

The interface card name.

Name

Ports for each FC-AL. For FC-AL A, that is A0 and A1, and for FC-AL B, that is B0
and B1.

Ports

Current state of port 0.

Loop LED (Port 0)

Current state of port 1.

Loop LED (Port 1)

Current state of daisy-chained drive cages (Unknown, Normal, Off, Green, Green
blink, Amber, Amber blink).

Loop Split

Current state of interface card.

Status LED

Link speed.

Link Speed

Drive cage firmware status (Current, Not Current, Unknown).

Firmware State

Current state of the current loop's CPU (Unknown, Normal, Failed, Degraded).

CPU State (Self)

Current state of other loop's CPU (Unknown, Normal, Failed, Degraded).

CPU State (Partner)

Viewing the Drive Cage Magazine Details

To view drive magazine details:
1.

Access the Drive Cages screen.

2.

In the upper pane of the Drive Cages screen, click the Summary tab and then click a drive
cage.

3.

In the lower pane, click the Magazines tab.

The Magazines tab appears as follows:

The following information is displayed:

Description

Column

Position of the drive magazine within the drive cage.

Position

The current state of the drive magazine. See

“System and Component

Status Icons” (page 41)

.

Status LED (for DC2 and DC4 drive cages)

The current state of the hot plug LED.

Hot Plug LED

(for DC2 and DC4 drive cages)

Number of disks in the drive magazine.

Disks

Viewing Drive Cages

81