beautypg.com

Raid level comparisons – HP Surestore Disk Array 12h and FC60 User Manual

Page 57

background image

Disk Array High Availability Features 57

Produ

ct Des

c

ript

ion

RAID Level Comparisons

To help you decide which RAID level to select for a LUN, the following tables compare the
characteristics for the supported RAID levels. Where appropriate, the relative strengths
and weakness of each RAID level are noted.

Note

RAID 3 is supported on Windows NT and Windows 2000 only.

Table 1

RAID Level Comparison: Data Redundancy Characteristics

RAID Level

Disk Striping

Mirroring

Parity

Handle multiple disk
failures?

RAID 0

Yes

No

No

No. RAID 0 offers no data
redundancy or protection
against disk failure. RAID 0
should only be used for non-
critical data. The failure of a
single disk in a RAID 0 LUN
will result in the loss of all
data on the LUN.

RAID 1

No

Yes

No

No

RAID 0/1

Yes

Yes

No

Yes, providing both disks in
a mirrored pair do not fail.

RAID 3

Yes

No

Yes

No

RAID 5

Yes

No

Yes

No