beautypg.com

HP Surestore Disk Array 12h and FC60 User Manual

Page 257

background image

Adding Capacity to the Disk Array 257

M

a

na
ging

the

Di
sk
Array

on HP-UX

6. Bind a LUN with the new disks using the management tool of your choice:

– To use SAM, see

"Binding a LUN" on page 267

– To use Array Manager 60, see

"Binding a LUN" on page 289

– To use STM, see

"Binding a LUN" on page 314

Note

After binding a LUN, you must execute the

insf -e

command to install special

device files on the LUN. This makes the LUN usable by the operating system.

7. Mount the file system on the LUN and restore the data to the LUN.

8. Disable WCE on the disk modules using the following command:

amutil -w

See

"Disabling Disk Module Write Cache Enable (WCE)" on page 302

for more

information.