beautypg.com

HP Surestore Disk Array 12h and FC60 User Manual

Page 364

background image

364 Introduction

Probable Cause/Recommended Action – The cause of the event and suggested steps
toward a solution. This information should be the first step in troubleshooting.

Figure 91

Sample EMS Hardware Event Notification Message

Notification Time: Thu Aug 6 15:18:03 1998

yourserver sent Event Monitor notification information:

/peripherals/events/mass_storage/LVD/enclosure/10_12.8.0.255.0.10.0 is

!=1.

Its current value is CRITICAL(5)

Event data from monitor:

Event Time: Thu Aug 6 15:18:03 1998

Hostname: yourserver.rose.hp.com IP Address: 15.43.212.175

Event ID: 0x0035ca2b9b00000002 Monitor: dm_ses_enclosure

Event # : 101 Event Class: I/O

Severity: Critical

Enclosure at hardware path 10/12.8.0.255.0.10.0: Hardware failure

Associated OS error log entry id(s): None

Description of Error:

The disk device is indicating a fault.

Probable Cause/Recommended Action:

The disk drive in slot 1 has failed. Check the connection, reseat,

or replace the disk drive.