HP Surestore Disk Array 12h and FC60 User Manual
Page 320

320 Status Conditions and Sense Code Information
AM60: READ FAILED
STM: FLT - 19
The disk array could not read from the disk.
Replace the failed disk.
AM60: WRONG BLOCK SIZE
STM: OFF - 22
The disk uses an incompatible block size (not 512 bytes).
Replace with a supported disk.
AM60: DISK LOCKED OUT
STM: UNSUPP
The disk is not supported.
Install a supported disk.
AM60: NON-SUPPORTED ID
STM: FLT - 33
The command made a request using an unsupported ID.
Retry the command with the proper parameters.
AM60: NO RESPONSE OR
DEFINED GLOBAL HOT
SPARE--DRIVE IS MISSING
STM: FLT - 35
The disk is not responding. It may have failed or been
removed.
Replace or reinstall the disk.
AM60: CAPACITY LESS
THAN MINIMUM
STM: OFF - 38
A disk was replaced by a disk with lower capacity.
Install disk with the proper capacity.
The disk is unsupported.
Install a supported disk.
AM60: NON-SUPPORTED
CHANNEL & ID
STM: FLT - 49
The command made a request to an unsupported channel
and ID.
Retry the command using the proper channel & ID.
AM60: FORMAT OR
RECONSTRUCT FAILED
STM: FLT - 51
The disk failed while being formatted or rebuilt.
Replace the disk.
AM60: WRITE FAILED
STM: FLT - 67
The disk array could not write to the disk.
Replace the failed disk.
AM60: UNDEFINED
STM: FLT - xxx
The disk is an unknown state.
AM60: FAILED VIA MODE
SELECT
STM: FLT - 83
The disk was failed using a host-initiated command.
Table 41
Disk Status Conditions (cont’d)
Status
Definition/Action