320 Status Conditions and Sense Code Information

AM60: READ FAILED
STM: FLT - 19

The disk array could not read from the disk.
Replace the failed disk.

AM60: WRONG BLOCK SIZE
STM: OFF - 22

The disk uses an incompatible block size (not 512 bytes).
Replace with a supported disk.

AM60: DISK LOCKED OUT
STM: UNSUPP

The disk is not supported.
Install a supported disk.

AM60: NON-SUPPORTED ID
STM: FLT - 33

The command made a request using an unsupported ID.
Retry the command with the proper parameters.

AM60: NO RESPONSE OR
DEFINED GLOBAL HOT
SPARE--DRIVE IS MISSING
STM: FLT - 35

The disk is not responding. It may have failed or been
removed.
Replace or reinstall the disk.

AM60: CAPACITY LESS
THAN MINIMUM
STM: OFF - 38

A disk was replaced by a disk with lower capacity.
Install disk with the proper capacity.

The disk is unsupported.
Install a supported disk.

AM60: NON-SUPPORTED
CHANNEL & ID
STM: FLT - 49

The command made a request to an unsupported channel
and ID.
Retry the command using the proper channel & ID.

AM60: FORMAT OR
RECONSTRUCT FAILED
STM: FLT - 51

The disk failed while being formatted or rebuilt.
Replace the disk.

AM60: WRITE FAILED
STM: FLT - 67

The disk array could not write to the disk.
Replace the failed disk.

AM60: UNDEFINED
STM: FLT - xxx

The disk is an unknown state.

AM60: FAILED VIA MODE
SELECT
STM: FLT - 83

The disk was failed using a host-initiated command.

Table 41

Disk Status Conditions (cont’d)

Status

Definition/Action