Installing the Disk Enclosures 169

Inst

alla

tion

Note

What if LUN 0 is on disks in the enclosure?
If any of the disks in the enclosure are part of LUN 0, you will not be able to
unbind the LUN before moving the disks. Instead, you must replace LUN 0 and
exclude any of the disks in the enclosures from LUN 0.

4. Power down the disk array, both the array controller enclosure and the disk enclosures.

5. Remove the disk enclosures from the rack. To remove the enclosures, reverse the steps

listed in

"Installing the Disk Enclosures" on page 160

.

6. Install the disk enclosures in the new rack following the instructions in

"Installing the

Disk Enclosures" on page 160

. Make sure the disk enclosure is configured properly for

the new disk array.

7. Bind a LUN with the new disks using the management tool of your choice:

– To use SAM, see

"Binding a LUN" on page 267

– To use Array Manager 60, see

"Binding a LUN" on page 289

– To use STM, see

"Binding a LUN" on page 314

Note

After binding a LUN, you must execute the

insf -e

command to install special

device files on the LUN. This makes the LUN usable by the operating system.