beautypg.com

HP Surestore Disk Array 12h and FC60 User Manual

Page 372

background image

372 Controller Enclosure Troubleshooting

Software errors occur
when attempting to
access controller or
disks

A Software function or

configuration problems

Check the appropriate software and
documentation to make sure the system is
set up correctly or that the proper command
was executed.

B Controller enclosure

power switches or main
circuit breakers in
rackmount cabinet
turned off

Make sure that all power switches are
turned on.

C Loose, disconnected, or

defective interface
cables

Check all the cables between the host,
controller enclosure, disk enclosure, and
other devices on the network. Make sure
they are undamaged (particularly fiber optic
cables) and securely attached.

D Improper ID settings

Make sure that the Fibre host IDs and SCSI
disk enclosure IDs are set properly for all
devices, particularly if you just removed or
added a new device to the network.

E Failed controller

enclosure or disk

Check the controller enclosure for a
controller module fault. If the Controller LED
on the front cover is turned on, look at each
controller module’s LED for a fault.
Check the disk enclosure for a disk fault. If
a failed disk is indicated, replace the disk.

F Failed controller

enclosure midplane

Replace the controller enclosure midplane.

Table 49 Master Troubleshooting Controller (cont’d)

Symptom

Possible Cause

Procedure