206 Verifying Disk Array Connection

Verifying Disk Array Connection

On Windows NT and Windows 2000

The HP Storage Manager 60 software is used to verify that the disk array is visible to the
Windows host. See the HP Storage Manager 60 User’s Guide for instructions on installing
and using the HP Storage Manager 60 software.

On HP-UX

To verify that the Disk Array FC60 is visible to the HP-UX host, run an ioscan by typing the
following:

ioscan -fn

An output will be displayed similar to that in

Figure 79

. The sample ioscan shown in the

figure includes entries for both disk array controllers: one at loop ID 6, and the other at
loop ID 7 (loop IDs are determined by the Fibre Channel Host ID switch setting on the back
of the controller enclosure). The virtual SCSI bus entries for both controllers are also
shown.

Note

The State of the each controller and its associated LUNs should be CLAIMED.
Any other condition indicates that the host is having difficulty accessing the
controller. If the State is not CLAIMED, refer to

"Troubleshooting" on page 359