Verifying disk array connection, On windows nt and windows 2000, On hp-ux – HP Surestore Disk Array 12h and FC60 User Manual
Page 206: On windows nt and windows 2000 on hp-ux

206 Verifying Disk Array Connection
Verifying Disk Array Connection
On Windows NT and Windows 2000
The HP Storage Manager 60 software is used to verify that the disk array is visible to the
Windows host. See the HP Storage Manager 60 User’s Guide for instructions on installing
and using the HP Storage Manager 60 software.
On HP-UX
To verify that the Disk Array FC60 is visible to the HP-UX host, run an ioscan by typing the
following:
ioscan -fn
An output will be displayed similar to that in
. The sample ioscan shown in the
figure includes entries for both disk array controllers: one at loop ID 6, and the other at
loop ID 7 (loop IDs are determined by the Fibre Channel Host ID switch setting on the back
of the controller enclosure). The virtual SCSI bus entries for both controllers are also
shown.
Note
The State of the each controller and its associated LUNs should be CLAIMED.
Any other condition indicates that the host is having difficulty accessing the
controller. If the State is not CLAIMED, refer to
for help in identifying the problem.