beautypg.com

HP Surestore Disk Array 12h and FC60 User Manual

Page 331

background image

Status Conditions and Sense Code Information 331

M

a

na
ging

the

Di
sk
Array

on HP-UX

29

04

Device Internal Reset

The controller has reset itself due to an internal error condition.

29

81

Default Configuration has been Created

The controller has completed the process of creating a default
logical unit. There is now an accessible logical unit that did not
exist previously. The host should execute its device scan to find
the new logical unit.

29

82

Controller Firmware Changed Through Auto Code Synchroni-
zation

The controller firmware has been changed through the Auto
Code Synchronization (ACS) process.

2A

01

Mode Parameters Changed

The controller received a request from another initiator to
change the mode parameters for the addressed logical unit.
This error notifies the current initiator that the change occurred.
This error may also be reported in the event that Mode Select
parameters changed as a result of a cache synchronization
error during the processing of the most recent Mode Select
request.

2A

02

Log Parameters Changed

The controller received a request from another initiator to
change the log parameters for the addressed logical unit. This
error notifies the current initiator that the change occurred. This
error is returned when a Log Select command is issued to clear
the AEN log entries.

Table 44

SCSI Sense Codes (cont’d)

Additional
Sense
Code

Additional
Sense Code
Qualifier

Interpretation