HP Surestore Disk Array 12h and FC60 User Manual
Page 331

Status Conditions and Sense Code Information 331
M
a
na
ging
the
Di
sk
Array
on HP-UX
29
04
Device Internal Reset
The controller has reset itself due to an internal error condition.
29
81
Default Configuration has been Created
The controller has completed the process of creating a default
logical unit. There is now an accessible logical unit that did not
exist previously. The host should execute its device scan to find
the new logical unit.
29
82
Controller Firmware Changed Through Auto Code Synchroni-
zation
The controller firmware has been changed through the Auto
Code Synchronization (ACS) process.
2A
01
Mode Parameters Changed
The controller received a request from another initiator to
change the mode parameters for the addressed logical unit.
This error notifies the current initiator that the change occurred.
This error may also be reported in the event that Mode Select
parameters changed as a result of a cache synchronization
error during the processing of the most recent Mode Select
request.
2A
02
Log Parameters Changed
The controller received a request from another initiator to
change the log parameters for the addressed logical unit. This
error notifies the current initiator that the change occurred. This
error is returned when a Log Select command is issued to clear
the AEN log entries.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier
Interpretation