beautypg.com

HP Surestore Disk Array 12h and FC60 User Manual

Page 286

background image

286 Managing the Disk Array Using Array Manager 60

Information for Controller A - 000A00A0B80673A6:

Controller Status = GOOD

Controller Mode = ACTIVE

Vendor ID = HP

Product ID = A5277A

Serial Number = 1T00310110

Firmware Revision = 04000304

Boot Revision = 04000200

HP Revision = HP08

Loop ID = 5

AL_PA = 0xE0

Preferred AL_PA = 0xE0

Controller Date = 05/08/2000

Controller Time = 13:38:53

Cache Battery Age = 0 to 89 days

NVSRAM Checksum = 0x353181DF

Information for Controller B - 000A00A0B80673A6:

Controller Status = GOOD

Controller Mode = ACTIVE

Vendor ID = HP

Product ID = A5277A

Serial Number = 1T90510188

Firmware Revision = 04000304

Boot Revision = 04000200

HP Revision = HP08

Loop ID = 4

AL_PA = 0xE1

Preferred AL_PA = 0xE1

Controller Date = 05/08/2000

Controller Time = 13:38:54

Cache Battery Age = 0 to 89 days

NVSRAM Checksum = 0x353181DF

Information for Disk System 1 (USSA02010592), Controller B:

SCSI Channel = 2

Thumbwheel Setting = 0

Controller Status = GOOD

Vendor ID = HP

Product ID = A5294A

Serial Number = USSA02010649

Firmware Revision = HP04

Information for Disk System 1 (USSA02010592), Controller A:

SCSI Channel = 1

Thumbwheel Setting = 0

Controller Status = GOOD

Vendor ID = HP

Product ID = A5294A

Serial Number = USSA02010592

i

i i

Controller Information - make sure the

following conditions are met:
- Both controllers should be ACTIVE
- The Loop ID must be unique for each

controller
- The three levels of firmware revisions must

be identical for each controller

Disk Enclosure Information -

make sure the following

conditions are met:
- The status of both controllers

(BCCs) should be GOOD
- The Thumbwheel Setting

must be the same for each

controller
- The Thumbwheel Setting

should correspond to the

enclosure position in the rack.

Uppermost enclosure set to 0,

next one down set to 1, etc.