Attaching SCSI Cables and Configuring the Disk Enclosure Switches 187

Inst

alla

tion

Attaching SCSI Cables and
Configuring the Disk Enclosure Switches

NOTE! It is critical that all SCSI cables be tightened securely. Use the
following steps to ensure the cable connectors are seated properly.

1. Connect the cable to the enclosure connector and tighten the
mounting screws finger tight.
2. Push on the connector and retighten the mounting screws. Repeat
once more.
3. Use a flat blade screwdriver to tighten the screw appropriately. Be
sure the screw is not cross-threaded.

There are two types of cabling configurations for the array: full-bus and split-bus. The
configuration you select is determined by a number of factors which are described in

Chapter 2, Topology and Array Planning

.

When you have determined which configuration you will use, refer to

"Full-Bus Cabling and

Switch Configuration" on page 188

” or

"Split-Bus Switch and Cabling Configurations" on

page 191

.

A Word About SCSI Terminators

Terminators need to be installed on both the disk enclosures and the controller enclosure.
On the controller enclosure, any unused SCSI connector must be terminated. On the disk
enclosure, not every connector requires termination. If a SCSI cable is connected to a BCC
connector, the other connector on the BCC must be terminated. If there is no SCSI cable
connected to the BCC, no terminator is required on either connector. A BCC that is
operating in split-bus mode will have a cable connected to each BCC. In this case, the
unused connector on each BCC must be terminated. See

Figure 69

or

Figure 71

.