beautypg.com

Isolating causes – HP Surestore Disk Array 12h and FC60 User Manual

Page 380

background image

380 SureStore E Disk System SC10 Troubleshooting

Isolating Causes

Table 52

lists the probable causes and solutions for problems you may detect on the disk

enclosure. When more than one problem applies to your situation, investigate the first
description that applies. The table lists the most basic problems first and excludes them
from subsequent problem descriptions.

Table 52

Disk Enclosure Troubleshooting Table

Problem
Description

HW Event
Category

LED State

Status

Probable Cause/Solution

The disk
enclosure does
not power on

none

System
Power LED
off

none

– Neither power cord is plugged in.
– The power switch is not pressed.
– AC breaker is tripped.
– AC power source has failed.
– The PDU/PDRU is defective.
– Power switch is defective.
– A faulty component is causing

power supplies to turn off.
Remove all components and
reinsert one at a time until the
faulty component is isolated.

System fault LED
is on

none

Power
Supply LED
off

Power
supply Not
Available

– The power supply is not plugged

in.

– The PDU/PDRU or primary power

source has failed.

Critical

Part Fault
LED on

Critical

A component has failed. See
problem descriptions below.

Buzzer sounds
when BCC
installed

Critical

BCC Fault
flashing

Critical

BCC DIP switch settings do not
match peer BCC switch settings.
Reset switches.

BCC Fault LED is
on

Critical

BCC Fault
on

Critical

BCC hardware is faulty. Replace the
BCC.

Fan LED is
amber

Critical

Amber

Critical

Fan has slowed or stopped. Replace
the fan.