Isolating causes – HP Surestore Disk Array 12h and FC60 User Manual
Page 380
380 SureStore E Disk System SC10 Troubleshooting
Isolating Causes
lists the probable causes and solutions for problems you may detect on the disk
enclosure. When more than one problem applies to your situation, investigate the first
description that applies. The table lists the most basic problems first and excludes them
from subsequent problem descriptions.
Table 52
Disk Enclosure Troubleshooting Table
Problem
Description
HW Event
Category
LED State
Status
Probable Cause/Solution
The disk
enclosure does
not power on
none
System
Power LED
off
none
– Neither power cord is plugged in.
– The power switch is not pressed.
– AC breaker is tripped.
– AC power source has failed.
– The PDU/PDRU is defective.
– Power switch is defective.
– A faulty component is causing
power supplies to turn off.
Remove all components and
reinsert one at a time until the
faulty component is isolated.
System fault LED
is on
none
Power
Supply LED
off
Power
supply Not
Available
– The power supply is not plugged
in.
– The PDU/PDRU or primary power
source has failed.
Critical
Part Fault
LED on
Critical
A component has failed. See
problem descriptions below.
Buzzer sounds
when BCC
installed
Critical
BCC Fault
flashing
Critical
BCC DIP switch settings do not
match peer BCC switch settings.
Reset switches.
BCC Fault LED is
on
Critical
BCC Fault
on
Critical
BCC hardware is faulty. Replace the
BCC.
Fan LED is
amber
Critical
Amber
Critical
Fan has slowed or stopped. Replace
the fan.