beautypg.com

Component status conditions – HP Surestore Disk Array 12h and FC60 User Manual

Page 321

background image

Status Conditions and Sense Code Information 321

M

a

na
ging

the

Di
sk
Array

on HP-UX

Component Status Conditions

Component status conditions are organized into the categories listed in

Table 42

. The

interpretation and action associated with a status depends on the component. See

Table 51

on page 379

for more information on Disk System SC10 component status.

The component status condition terminology used by Array Manager 60 (AM60) may differ
from that used by STM. Both terms are identified in the table.

Table 42 Component Status Conditions

Status

Description

AM60: Good
STM: Optimal

The component is operating normally.

AM60: Non-critical
STM: Fault - 3

A component or condition such as temperature or voltage
has exceeded warning limits.

Although immediate action is not required, the cause of
the non-critical status should be investigated and
corrected if necessary.

AM60: Critical
STM: Fault - 2

A component has failed or a condition such as
temperature or voltage has exceeded critical limits.
Immediate action is required.

AM60: Not Installed
STM: Not Present

The component is not installed.

AM60: Unknown
STM: Fault - 0

The status of the component cannot be determined.