HP Surestore Disk Array 12h and FC60 User Manual
Page 329
Status Conditions and Sense Code Information 329
M
a
na
ging
the
Di
sk
Array
on HP-UX
11
00
Unrecovered Read Error
An unrecovered read operation to a drive occurred and the con-
troller has no redundancy to recover the error (RAID 0,
degraded RAID 1, degraded mode RAID 3, or degraded RAID
5).
11
8A
Miscorrected Data Error - Due to Failed Drive Read
A media error has occurred on a read operation during a recon-
figuration operation,
User data for the LBA indicated has been lost.
18
02
Recovered Data - Data Auto Reallocated
The controller recovered a read operation to a drive and no fur-
ther action is required by the host. Auto reallocation may not
have been used, but this is the only standard ASC/ ASCQ that
tells the initiator that no further actions are required by the
driver.
1A
00
Parameter List Length Error
A command was received by the controller that contained a
parameter list and the list length in the CDB was less than the
length necessary to transfer the data for the command.
20
00
Invalid Command Operation Code
The controller received a command from the initiator that it
does not support.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier
Interpretation