beautypg.com

Managing the disk array using array manager 60 – HP Surestore Disk Array 12h and FC60 User Manual

Page 276

background image

276 Managing the Disk Array Using Array Manager 60

Managing the Disk Array Using Array Manager 60

The Array Manager 60 command line utilities allow you to configure, control, and monitor
all aspects of disk array operation. Array Manager 60 is intended for performing the more
advanced tasks involved in managing the disk array.

The Array Manager 60 utilities and the tasks they are used to perform are summarized in

Table 33

and

Table 34

.

Note

You must log in as superuser or root to use the Array Manager 60 utilities to
manage the disk array.

Table 33

Array Manager 60 Task Summary

Task Command

Capacity Management

Binding a LUN

amcfg -L : -d ,.....
-r

Unbinding a LUN

amcfg -D [-force]

Calculating LUN Capacity

amcfg -C -d channel:ID,channel:ID...
-r -s

Adding a Global Hot Spare

ammgr -h channel:ID

Removing a Global Hot Spare

ammgr -d channel:ID

Identifying Disks

amdsp -d

Changing LUN Ownership

amcfg -M -c

Replacing a LUN

amcfg -R : -d ,.....
-r

Disk Array Status

Displaying Status Information

amdsp

Listing Disk Array IDs

amdsp -i

Rescanning for Disk Arrays

amdsp -R