HP Surestore Disk Array 12h and FC60 User Manual

Page 283

background image

Managing the Disk Array Using Array Manager 60 283

M

a

na
ging

the

Di
sk
Array

on HP-UX

Command Example

The following example all status information for disk array Array1.

amdsp -a Array1

A sample out put from this command is shown in

Figure 88

. The important fields are

identified with the normal values.

Note

Missing UTM LUN 31
If the required patches for HP08 firmware are not installed on the host, the host
will not recognize or display UTM LUN 31. If LUN 31 is not displayed, install
the required patches as described in

"Installing the Disk Array FC60 Software"

on page 214

.

-a

All status. This option displays all the information returned by the
preceding options.

-p

Hardware path information. Displays hardware path information for
the controller corresponding to the specified device file.

-r

Rebuild status. Display the progress of any rebuilds occurring on the
disk array.

-A

Array server status.

Table 37

Command Options for Displaying Disk Array Status (cont’d)

Option

Status Information Displayed