HP Surestore Disk Array 12h and FC60 User Manual
Page 335
Status Conditions and Sense Code Information 335
M
a
na
ging
the
Di
sk
Array
on HP-UX
3F
D0
Write Back Cache Battery Has Been Discharged
The controller’s battery management has indicated that the
cache battery has been discharged.
3F
D1
Write Back Cache Battery Charge Has Completed
The controller’s battery management has indicated that the
cache battery is operational.
3F
D8
Cache Battery Life Expiration
The cache battery has reached the specified expiration age.
3F
D9
Cache Battery Life Expiration Warning
The cache battery is within the specified number of weeks of
failing.
3F
E0
Logical Unit Failure
The controller has placed the logical unit in a "dead" state. User
data and/ or parity can no longer be maintained to ensure avail-
ability. The most likely cause is the failure of a single drive in
non-redundant configurations or a second drive in a configura-
tion protected by one drive. The data on the logical unit is no
longer accessible.
3F
EB
LUN marked DEAD due to Media Error Failure during SOD
An error has occurred during interrupted write processing caus-
ing the LUN to transition to the DEAD state
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier
Interpretation