HP Surestore Disk Array 12h and FC60 User Manual
Page 287

Managing the Disk Array Using Array Manager 60 287
M
a
na
ging
the
Di
sk
Array
on HP-UX
Vendor ID = HP
Product ID = A5277A
Array ID = 000A00A0B80673A6
Array alias = Array1
-----------------------------------------
Overall State of Array = READY
Array configuration:
Cache Block Size = 4 KB / 4 KB
Cache Flush Threshold = 80 % / 80 %
Cache Flush Limit = 100 % / 100 %
Cache Size = 256MB / 256MB
Vendor ID = HP
Product ID = A5277A
Array ID = 000A00A0B80673A6
Array alias = Array1
-----------------------------------------
Array Controller Subsystem:
Controller A: GOOD
Controller B: GOOD
PS 1: GOOD
PS 2: GOOD
Fan 1: GOOD
Fan 2: GOOD
Temp Sensor: GOOD
Battery: GOOD
Disk System 1 - USSA02010592:
BCC Controller B: GOOD
BCC Controller A: GOOD
PS 1: GOOD
PS 2: GOOD
Fan 1: GOOD
Fan 2: GOOD
Temp Sensor: GOOD
Disk System 2 - USSA02010595:
BCC Controller B: GOOD
BCC Controller A: GOOD
PS 1: GOOD
PS 2: GOOD
Fan 1: GOOD
Fan 2: GOOD
Temp Sensor: GOOD
No LUNs are currently rebuilding
Component status - all hardware
components should be GOOD
Cache settings
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)